8.1 State the purpose of a consumer’s unit.
The purpose of the consumer
unit is to house the different components
used:-
1. Isolation of the consumer
unit from the supply.
2. Protections for Circuit segregation (separation)
8.2 List
the standard sizes of main cables entering a consumer’s unit.
The standard
sizes of main cables entering a
consumer’s unit are:
1.
6 mm2
2.
10 mm2
8.3 State the common
ratings of main fuse/circuit-breaker likely to be found in a consumer's unit installed in
domestic premises.
Ratings
depend on the total maximum load of the outgoing circuits .
Ratings of main fuses
- 45A
- 60A
Ratings of main circuit breakers
- 40A
- 45A
- 63A
- 100A
8.4 List the
standard size of fuse likely to be found in a consumer’s unit.
Fuse
|
Colour
|
Typical Uses
|
5 amp
|
White
|
Lighting / small plug circuits
|
15 amp
|
Blue
|
Immersion/storage heaters
|
20 amp
|
Yellow
|
Smaller radial circuits / water heaters
|
30 amp
|
Red
|
Ring circuits (sockets), cookers, showers, radial circuits
|
45 amp
|
Green
|
Cookers/showers
|
8.5 Interpret the
colour code of fuses.
Consumer unit with fuses
Consumer
unit with Circuit Breakers
Note: Circuit breakers are replacing fuses as the latter are becoming obsolete.
Regulations recommend that New buildings must be equipped with these devices and at least a RCD.
Ratings of outgoing circuit breakers
Circuit breaker
|
Typical Uses
|
6 amp
|
Lighting
|
10 amp
|
Lighting / small plug
circuits
|
16 amp
|
Immersion/storage heaters
|
20 amp
|
Smaller radial circuits / water heaters
|
25 amp
|
|
32 amp
|
Ring circuits (sockets), cookers, showers, radial circuits
|
40 amp
|
|
45 amp
|
Cookers/showers
|
MAIN SWITCH